Part No. or keyword £º  
 
;
 

Standard Models - Single Dial

  • Most units can easily be supplied with Type N or BNC connectors, see below for details

  • Attenuation increases in clockwise direction

  • 30 degrees with stops at minimum and maximum

  • Click on pictures for outline drawings

 

RF INPUT POWER:

2 watt average
1 kW peak

RF CONN:

SMA Female std.

IMPEDANCE:

50 Ohms

OPERATING
TEMPERATURE:

-20¡ã C to +85¡ã C

Model No.*
AS013-10-1

Model No.*
AS013-60-10

Model No.**
AS013-70-10

Freq Range..........DC-2500 MHz
Atten Range.........0-10 dB in
                             1 dB steps

Attenuation Accuracy:
DC-1100 MHz.......+/-0.25dB max
1100-2200 MHz....+/-0.5dB max
2200-2500 MHz....+/-0.6dB max


VSWR:
DC-1100 MHz..........1.25:1 max
1100-2000 MHz.........1.5:1 max

Insertion Loss:
DC-1100 MHz.........0.25dB max
1100-2000 MHz.......0.5dB max
Freq Range........DC-2200 MHz
Atten Range.......0-60 dB in
                           10 dB steps

Attenuation Accuracy:
DC-500 MHz......+/-0.5dB or 1%
500-1000 MHz....+/-0.5dB or 2%
1000-2000 MHz...+/-0.5dB or 3%


VSWR:
DC-1000 MHz...........1.2:1 max
1000-2000 MHz........1.4:1 max

Insertion Loss:
DC-1000 MHz.........0.3dB max
1000-2000 MHz.......0.5dB max
Freq Range........DC-2500 MHz
Atten Range........0-70 dB in
                           10 dB steps

Attenuation Accuracy:
DC-500 MHz......+/-0.5dB or 1%
500-1000MHz.....+/-0.5dB or 2%
1000-2500MHz...+/-0.5dB or 3%

VSWR:
DC-1000 MHz...........1.2:1 max
1000-2000 MHz........1.4:1 max
2000-2500 MHz........1.5:1 max

Insertion Loss:
DC-1000 MHz.........0.3dB max
1000-2000 MHz.......0.5dB max
2000-2500 MHz.......0.6dB max
*These models available with SMA-F connectors only.
**
For Type N Female connectors change P/N to AS023 Example: AS013-70-10 becomes AS023-70-10
 For BNC Female connectors change P/N to AS073 Example: AS013-70-10 becomes AS073-70-10
 